wacom_intuos_pad() uses wacom->pad_input throughout, but pad_input can be NULL when wacom_setup_pad_input_capabilities() returns -ENODEV during a successful probe. Place the guard after the data[0] report-ID check and return 1 so the report is consumed. Returning 0 would let the caller fall through to wacom_intuos_inout(), which would misparse the pad packet as a pen event. Fixes: 10059cdc0ad0 ("Input: wacom - split out the pad device for Intuos/Cintiq") Signed-off-by: Jinmo Yang Co-Authored-By: Claude Opus 4.6 --- drivers/hid/wacom_wac.c | 6 ++++++ 1 file changed, 6 insertions(+) diff --git a/drivers/hid/wacom_wac.c b/drivers/hid/wacom_wac.c index aa08afb3c5ef..acf24360d547 100644 --- a/drivers/hid/wacom_wac.c +++ b/drivers/hid/wacom_wac.c @@ -578,6 +578,12 @@ static int wacom_intuos_pad(struct wacom_wac *wacom) data[0] == WACOM_REPORT_CINTIQPAD)) return 0; + if (!input) { + dev_warn_once(&container_of(wacom, struct wacom, wacom_wac)->hdev->dev, + "%s: pad_input is NULL\n", __func__); + return 1; /* consume the report to prevent fall-through */ + } + if (features->type >= INTUOS4S && features->type <= INTUOS4L) { buttons = (data[3] << 1) | (data[2] & 0x01); ring1 = data[1]; -- 2.53.0