A reset leaves spectral_mode set to SPECTRAL_BACKGROUND, but resets the spectral registers and receive filter. The driver therefore still reports a background scan even though the hardware no longer produces FFT samples. Re-trigger background spectral scanning after reset recovery so the software and hardware state match again. Do not re-trigger spectral scanning in disabled, manual, channel-scan, radar, or off-channel modes. Assisted-by: Claude:opus-5 Signed-off-by: Nick Hainke --- drivers/net/wireless/ath/ath9k/main.c | 12 ++++++++++++ 1 file changed, 12 insertions(+) diff --git a/drivers/net/wireless/ath/ath9k/main.c b/drivers/net/wireless/ath/ath9k/main.c index 740a6fc7b067..00e587fe6ee3 100644 --- a/drivers/net/wireless/ath/ath9k/main.c +++ b/drivers/net/wireless/ath/ath9k/main.c @@ -231,6 +231,17 @@ static bool ath_prepare_reset(struct ath_softc *sc) return ret; } +static void ath_restore_spectral_scan(struct ath_softc *sc, bool start) +{ + struct ath_common *common = ath9k_hw_common(sc->sc_ah); + + if (!start || sc->cur_chan->offchannel || sc->hw->conf.radar_enabled || + sc->spec_priv.spectral_mode != SPECTRAL_BACKGROUND) + return; + + ath9k_cmn_spectral_scan_trigger(common, &sc->spec_priv); +} + static bool ath_complete_reset(struct ath_softc *sc, bool start) { struct ath_hw *ah = sc->sc_ah; @@ -269,6 +280,7 @@ static bool ath_complete_reset(struct ath_softc *sc, bool start) ath_restart_work(sc); ath_txq_schedule_all(sc); } + ath_restore_spectral_scan(sc, start); sc->gtt_cnt = 0; -- 2.55.0