When the PPS channel configuration was implemented, the channel index for the periodic outputs was configured as the hardware channel number. The sysfs interface uses a logical channel index, and rejects numbers greater than `n_per_out` (see period_store() in ptp_sysfs.c). That property was left at 1, since the driver implements channel selection, not simultaneous operation of multiple PTP hardware timer channels. A second check in fec_ptp_enable() returns -EOPNOTSUPP when the two channel numbers disagree, making channels 1..3 unusable from sysfs. Fix by removing this redundant check in the FEC PTP driver. Fixes: 566c2d83887f ("net: fec: make PPS channel configurable") Signed-off-by: Buday Csaba --- drivers/net/ethernet/freescale/fec_ptp.c | 3 --- 1 file changed, 3 deletions(-) diff --git a/drivers/net/ethernet/freescale/fec_ptp.c b/drivers/net/ethernet/freescale/fec_ptp.c index 4b7bad9a485d..56801c2009d5 100644 --- a/drivers/net/ethernet/freescale/fec_ptp.c +++ b/drivers/net/ethernet/freescale/fec_ptp.c @@ -545,9 +545,6 @@ static int fec_ptp_enable(struct ptp_clock_info *ptp, if (rq->perout.flags) return -EOPNOTSUPP; - if (rq->perout.index != fep->pps_channel) - return -EOPNOTSUPP; - period.tv_sec = rq->perout.period.sec; period.tv_nsec = rq->perout.period.nsec; period_ns = timespec64_to_ns(&period); base-commit: 8a63baadf08453f66eb582fdb6dd234f72024723 -- 2.39.5