From: Sylvain Chouleur The X and Y coordinates in a CMN/CI-700 node ID are encoded in 2 bits each for any mesh up to 4x4 (7-bit node IDs), and in 3 bits each for larger meshes (9-bit node IDs). The width does not shrink for smaller meshes: a 2x2 mesh still uses 2 bits per coordinate. arm_cmn_xyidbits() derives the width from the actual mesh dimensions, which yields 1 bit for a mesh with both dimensions <= 2. On such a mesh arm_cmn_node_to_xp() then decodes every device on the X=1 column into the wrong XP: X=1,Y=0 devices are attributed to XP (0,1), and X=1,Y=1 devices to an index past the end of the XP array. Their PMU events end up programmed into another XP's DTM, with the port/device select of the intended XP, so the counters silently read zero while the rest of the mesh works. Observed on a CI-700 r3 with a 2x2 mesh (part 0x43a), where the SBSX and HN-D nodes on the X=1 column never counted although the XP flit counters showed the traffic. Forcing a minimum of 2 coordinate bits matches the documented node ID format and makes all nodes count; the minimum had been there until the node ID refactor dropped it. Fixes: e79634b53e39 ("perf/arm-cmn: Refactor node ID handling. Again.") Cc: stable@vger.kernel.org Signed-off-by: Sylvain Chouleur --- drivers/perf/arm-cmn.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-) diff --git a/drivers/perf/arm-cmn.c b/drivers/perf/arm-cmn.c index 68a096c1fe6b..5f369c7a7a35 100644 --- a/drivers/perf/arm-cmn.c +++ b/drivers/perf/arm-cmn.c @@ -406,7 +406,8 @@ struct arm_cmn_nodeid { static int arm_cmn_xyidbits(const struct arm_cmn *cmn) { - return fls((cmn->mesh_x - 1) | (cmn->mesh_y - 1)); + /* Node IDs never use fewer than 2 bits per XP coordinate */ + return fls((cmn->mesh_x - 1) | (cmn->mesh_y - 1) | 2); } static struct arm_cmn_nodeid arm_cmn_nid(const struct arm_cmn_node *dn) --- base-commit: 4dce97c6c265544342e716e62fd24bbb232590c5 change-id: 20261125-arm-cmn-xyidbits-16076edf28a2 Best regards, -- Sylvain Chouleur