5.15-stable review patch. If anyone has any objections, please let me know. ------------------ From: Arnav Kapoor commit e5f7a6684a23d9b20184a81b4ebded3b3504ccdc upstream. inv_mpu_magn_get_scale() returns st->magn_raw_to_gauss[chan->address], where magn_raw_to_gauss[] holds one coefficient per axis, computed in inv_magn_init() from the per-axis factory sensitivity adjustment values (ASAX, ASAY, ASAZ) of the AK8975/AK8963 magnetometer. However INV_MPU9X50_MAGN_CHAN() never sets .address, so it is 0 for all three magnetometer channels. As a result the Y and Z channels report the scale computed from the X axis adjustment value, and userspace scales the Y and Z readings with the wrong per-axis calibration. Set .address to the axis index (0 for X, 1 for Y, 2 for Z) in the channel macro, matching the order used to fill magn_raw_to_gauss[]. Fixes: b1392de06184 ("iio: imu: inv_mpu6050: add MPU925x magnetometer support") Signed-off-by: Arnav Kapoor Acked-by: Jean-Baptiste Maneyrol Cc: stable@vger.kernel.org Signed-off-by: Jonathan Cameron Signed-off-by: Greg Kroah-Hartman --- drivers/iio/imu/inv_mpu6050/inv_mpu_core.c | 2 ++ 1 file changed, 2 insertions(+) --- a/drivers/iio/imu/inv_mpu6050/inv_mpu_core.c +++ b/drivers/iio/imu/inv_mpu6050/inv_mpu_core.c @@ -1153,6 +1153,8 @@ static const unsigned long inv_mpu_scan_ .type = IIO_MAGN, \ .modified = 1, \ .channel2 = _chan2, \ + /* index of the axis in magn_raw_to_gauss[] */ \ + .address = (_chan2) - IIO_MOD_X, \ .info_mask_separate = BIT(IIO_CHAN_INFO_SCALE) | \ BIT(IIO_CHAN_INFO_RAW), \ .scan_index = _index, \