Add the SiFive FU740-C000 PLIC compatible string to the binding documentation. This follows the SiFive IP versioning scheme which requires SoC-specific compatible strings for proper hardware identification, even when the IP blocks are functionally identical. Signed-off-by: Max Hsu --- .../devicetree/bindings/interrupt-controller/sifive,plic-1.0.0.yaml | 1 + 1 file changed, 1 insertion(+) diff --git a/Documentation/devicetree/bindings/interrupt-controller/sifive,plic-1.0.0.yaml b/Documentation/devicetree/bindings/interrupt-controller/sifive,plic-1.0.0.yaml index e0267223887e..351d26ab1956 100644 --- a/Documentation/devicetree/bindings/interrupt-controller/sifive,plic-1.0.0.yaml +++ b/Documentation/devicetree/bindings/interrupt-controller/sifive,plic-1.0.0.yaml @@ -63,6 +63,7 @@ properties: - eswin,eic7700-plic - microchip,pic64gx-plic - sifive,fu540-c000-plic + - sifive,fu740-c000-plic - spacemit,k1-plic - starfive,jh7100-plic - starfive,jh7110-plic -- 2.43.0